Leaking Fort Lauderdale Water Heater Pressure Relief Valve

Posted by on Dec 9, 2014 in Gas Water Heater Repair Fort Lauderdale, Water Heater Repair Fort Lauderdale

The pressure relief valve of a water heater has a vital task – seeing to it the water heater tank does not blow up. So with that in mind, Water Heater Repair Fort Lauderdale wishes to ensure property owners know how to best look after it. They will leak when the valve wears out or when the water storage tank pressure gets higher then the relief point.Hot Water Heater Repair Fort Lauderdale

We advise that a minimum of two times a year, property owners test to ensure the pressure relief valve, or T&P valve as we will call it, is working correctly. All one needs to do is raise the manage for a few seconds and let go of it. It ought to snap back to its initial position. When it is raised, one may hear the sound of pressure being released from it, much like the sound of air coming out of a tire pump when being detached. Also, a little water could come out also. Both are normal. If the valve has not been tested for a number of years, it may stick at first too.

Nevertheless, if the handle does not snap back, or if it continues to leak a little water, that is not regular. If it still leakages some, raise the handle a couple of more times to see if it will re-seat itself. You might wish to wait a day or so it see if it re-seats itself before presuming it has to be replaced.

Hot Water Heater Repair Fort Lauderdale would like to handle any T&P valve replacements for you, so though water heaters are usually fairly upkeep free, there are some safety preventative measures one should bear in mind. With that in mind here is a summary of a pressure relief valve replacement.

1. The gas to the water heater has to be turned off, or the breaker for an electrical water heater.
2. The cold water cut-off valve needs to be closed .
3. The valve below the T&P valve has to be opened to drain a little water in order to relieve some of the pressure in the storage tank.
4. The overflow pipe of the T&P valve needs to be taken off. It might need to be cut off if it is soldered or securely glued.
5. The pressure relief valve needs to be unscrewed with a pipe wrench.
6. Wrap the new T&P valve with Teflon tape and screw it in place. Make sure the overflow pipe opening is positioned away from the storage tank.
7. Reattach the drain pipe, likewise making use of new Teflon tape.
8. Turn the water back on, and analyze your work for any leaks.

The following video offers a summary of this procedure: